For use in in Thermosyphon Solar Systems and
Normal Geysers
Description
Use as a geyser timer or use as timer on a
thermosyphon solar system
- Clear
display of water temperature, time, day, heating mode and malfunction
conditions.
- Auto
or manual heating.
- Easy
temperature setting to your requirements (30 – 75°C) factory default is
55°C.
- Four
different temperature settings.
- Daily
programmable timer with four timer settings.
- Error
conditions alert by warning code E2 to E5 and E7.
- Electronic
thermostat with mechanical thermal cut-out at 90°C. Please note the
cut-out temperature for solar systems expected to reach temperatures above
this temperature.
Technical Parameters
- Operating
voltage 230VAC / 50HZ.
- Main
relay contact rating 30AMP (Max 4KW).
- Operating
voltage range 220V – 250V AC.
- Temperature
display range 0 – 99°C (“-5” when below -5°C “EA” when above 99°C).
- High
temperature warning above 84°C.
- Temperature
setting ranges 30 – 75°C (heating water electrically).
- Heat
failure – when increase at a rate of less than 4°C per hour.
- Mechanical
thermal cut-out at 90°C. Please note the cut-out temperature for systems
expected to reach temperatures above this temperature.
- Dry
heat detection – empty cylinder.
- Temperature
tolerance ± 2%.
- Temperature
differential setting 1°C.
- Switching
differential 6°C.
- Temperature
probe failure detection for tank
- Temperature probe range for geyser is -30 to + 130°C.
- Download Manual
Geyserwise TSE1
- Brand: Geyserwise
- Product Code: TSE013 & TSE014
- Availability: 10
-
R1,394.82
- Ex VAT: R1,212.89
Tags: Geyserwise TSE1