For use in pumped solar water heating systems
Smart Wifi Geyser Controller. Download the Tuya Smart App
and manage your geyser from your phone anywhere in the world.
Using the app will enable you to:
- View
your geyser temperatures
- Set
your temperatures
- Switch
Your Geyser On And Off from virtually anywhere.
- Manage
Your Geyser like a wifi geyser controller.
Description
Use as a geyser timer or
use as timer on a thermosyphon solar system.
- Clear
display of water temperature, time, day, heating mode and malfunction
conditions.
- Auto
or manual heating.
- Easy
temperature setting to your requirements (30 – 75°C) factory default is
55°C.
- Four
different temperature settings.
- Daily
programmable timer with four time settings.
- Error
conditions alert by warning code E1 to E7.
- Electronic
thermostat with mechanical thermal cut-out at 90°C. Please note the
cut-out temperature for solar systems expected to reach temperatures above
this temperature.
Use as timer and differential control on 12V or
220V pumped solar system.
- Clear
display of water temperature, time, day, heating mode and malfunction
conditions on solar system and geyser.
- Auto
or manual heating.
- Easy
temperature setting to your requirements (30 – 75°C) factory default is
55°C.
- Four
different temperature settings.
- Daily
programmable timer with four time settings.
- Error
conditions alert by warning code E1 to E9.
- Electronic
thermostat with mechanical thermal cut-out at 90°C. Please note the
cut-out temperature for systems expected to reach temperatures above this
temperature.
- Differential
controller 12V and 220V systems.
Technical Parameters
- Operating
voltage 230VAC / 50HZ.
- Main
Relay contact rating 30AMP (Max 4KW).
- Secondary
relays pump and solenoid 5Amp.
- Operating
voltage range 220V – 250V AC.
- Earth
leakage protection at 25MA action time = 0,1 second.
- Temperature
display range 0 – 99°C (“-5” when below -5°C “EA” when above 99°C).
- High
temperature warning above 84°C.
- Temperature
setting ranges 30 – 75°C (heating water electrically).
- Heat
failure – when increase at a rate of less than 4°C per hour.
- Electronic
thermostat with mechanical thermal cut-out at 90°C.
- Dry
heat detection – empty cylinder.
- Temperature
tolerance ± 2%.
- Temperature
differential setting 1°C.
- Switching
differential 6°C.
- 2nd
temperature probe for solar.
- Solar
differential 7°C – 15°C. Default is 7°C.
- Temperature
probe failure detection for both collector and tank.
- Temperature
probe range for geyser is -30 to + 130°C.
- Temperature
probe range for collector is -30 to + 260°C.
- Isolate
both L + N when in off state.
- Collector antifreeze protection at 0°C – 10°C. Default is 5°C.
- Download Manual
Geyserwise Max with Tuya Module
- Brand: Geyserwise
- Product Code: GEY111&GEY112
- Availability: 10
-
R3,151.72
- Ex VAT: R2,740.63
Tags: Geyserwise Max with Tuya Module