Model | SUN-6K-SG04LP1-EU-SM2 |
Battery Input Data |
|
Battery Type | Lead-acid or Lithium-ion |
Battery Voltage Range(V) | 40-60 |
Max.Charging Current(A) | 135 |
Max.Discharging Current(A) | 135 |
Charging Strategy for Li-ion Battery | Self-adaption to BMS |
Number of battery input | 1 |
PV String Input Data |
|
Max. PV
Access Power (W)
|
12000 |
Max PV Input Power(W) | 9600 |
Max PV Input Voltage(V) | 500 |
Start-up Voltage(V) | 125 |
MPPT Voltage Range(V) | 150-425 |
Rated PV Input Voltage(V) | 370 |
Max Input Short-Circuit Current(A) | 27+27 |
Max Operating PV Input Current(A) | 18+18 |
No.of MPP Trackers/No.of String Per MPP Tracker | Mppt 1 has 2 inputs, Mppt 2 has 1input, |
AC Input/Output Data |
|
Rated AC Input/Output Active Power(W) | 6000 |
Max AC Input/Output Apparent Power (VA) | 6600 |
Peak Power (off-grid)(W) | 2 times of rated power,10s |
Rated AC Input/Output Current(A) | 27.3/26.1 |
Max AC Input/Output Current(A) | 30/28.7 |
Max Continuous AC Passthrough (grid to load)(A) | 40 |
Rated Input/Output Voltage/Range(V) | 220V/230 0.85Un-1.1Un |
Grid Connection Form | L+N+PE |
Rated Input/Output Grid Frequency/Range | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz |
Power Factor Adjustment Range | 0.8 leading to 0.8lagging |
Total Current Harmonic Distortion THDi | <3% (of nominal power) |
DC Injection Current | <0.5%ln |
Efficiency |
|
Max Efficiency | 97.60% |
Euro Efficiency | 96.50% |
MPPT Efficiency | >99% |
Equipment Protection | |
Integrated | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, |
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, | |
Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), | |
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, | |
DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level | |
Surge Protection Level | TYPE II(DC),TYPE II(AC) |
Interface | |
Communication Interface | RS485/RS232/CAN |
Monitor Mode
|
GPRS/WIFI/Bluetooth/4G/LAN(optional) |
General Data |
|
Operating Temperature Range | -40 to+60℃,>45℃ Derating |
Permissible Ambient Humidity | 0~100% |
Permissible Altitude | 2000m |
Noise | <30 |
Ingress Protection(IP) Rating | IP 65 |
Inverter Topology | Non-Isolated |
Over Voltage Category | OVC II(DC),OVC III(AC) |
Cabinet size(W*H*D)[mm] | 376*470*241.5(Excluding connectors and brackets) |
Weight[kg] | 19 |
Warranty | 5 Year standard |