Find us on Facebook
Hellopeter
Google reviews
  • MECER Axpert MKS Hybrid off-grid inverter 3kVA/3kW 1,500W MPPT 24V

24 month warranty MECER carry in warranty. Free shipping.

MECER CODE: SOL-I-AX-3MPLUS24

MECER Axpert MKS is equipped with a 1500 MPPT solar charge controller to regulate DC power from the solar array for charging the battery bank. Transformerless design provides reliable power conversion in compact size. Besides, it’s worry-free to start up motor-type loads such as refrigerators, motors, pumps, compressors and laser printers as well as electronic loads like TVs, Computers, power tool and battery chargers. Requires a minimum of 2 x 12V batteries.

  • Pure sine wave inverter
  • Output power factor 1
  • Built in 1500W MPPT solar charge controller. Recommended for backup or solar.
  • Selectable input voltage range for home appliances and personal computers
  • Selectable charging current based on application
  • Configurable AC/Solar input priority via LCD setting
  • Compatible to mains voltage or generator power
  • Auto restart while AC is recovering
  • Overload and short circuit protection
  • Battery equalization for optimized battery performance and life-cycle 
  • Cold start function
  • NOT Parallel compatible 
  • Recommended for backup purposes and/or solar

Click here for technical specifications

Specifications and features
Product CodeSOL-I-AX-3MPLUS24spacer
ModelAxpert MKS 3K-24 Plus
RATED POWER3000VA/2400W
INPUT
Voltage120 VAC or 230 VAC
Selectable Voltage Range95-140 VAC or 170-280 VAC (For Personal Computers)
65-140 VAC or 90-280 VAC (For Home Appliances)
Frequency Range50 Hz/60 Hz (Auto sensing)
OUTPUT
AC Voltage Regulation (Batt. Mode)110/120 VAC ± 5% (User selectable) or 230VAC ± 5%
Surge Power6000VA
Efficiency (Peak)90% - 93%
Transfer Time10 ms (For Personal Computers) ; 20 ms (For Home Appliances)
WaveformPure sine wave
BATTERY & AC CHARGER
Battery Voltage24 VDC
Floating Charge Voltage27 VDC
Overcharge Protection31 VDC
Maximum Charge Current20 A or 20 A / 30 A
SOLAR CHARGER
Maximum PV Array Power1500 W
MPPT Range @ Operating Voltage30~ 115 VDC or 60 ~ 115 VDC
Maximum PV Array Open Circuit Voltage145 VDC
Maximum Charging Current60A
Maximum Efficiency0.98
Standby Power Consumption2 W
PHYSICAL
Dimension, D x W x H (mm)140 x 295 x 479
Net Weight (kgs)11.5
OPERATING ENVIRONMENT
Humidity5% to 95% Relative Humidity(Non-condensing)
Operating Temperature0°C - 55°C
Storage Temperature-15°C - 60°C


NOTE:

All inverters must be installed by a qualified electrical wireman or Master electrician with a valid registration with the Department of Labour. A valid electrical certificate of compliance (Coc) must be issued once installed, specific to the installation of the backup or solar system. The installation must be compliant with SANS 10142 and ALL its parts. Any warranty claim submitted without installation photos, a valid Coc and proof of a qualified wireman/master electrician installing the unit, can be rejected and will render the warranty claim null at void.

The warranty does not cover damage resulting from:

  • ·         Power surge
  • ·         Under-voltage
  • ·         Over-voltage
  • ·         Lightning
  • ·         Corrosion
  • ·         Sea spray
  • ·         Condensation
  • ·         Water damage
  • ·         Dust or any solid particles
  • ·         Sand
  • ·         Insects
  • ·         Lizards
  • ·         Excessive heat exposure
  • ·         Weather damage
  • ·         Negligence by the installer or homeowner
  • ·         Incorrect installation
  • ·         Inadequate protection device rating
  • ·         Tampering (broken seal)
  • ·         Dirty filters
  • ·         Exceeding the maximum power rating, current or voltage for the input solar circuit, DC battery input, AC input and AC output.

The warranty will be void if the unit is:

  • ·         Not installed as per manufacturers specifications
  • ·         Not installed with a minimal 40kA surge protection unit for both live and neutral wires from the AC incoming supply
  • ·         Not installed with a minimal 40kA surge protection unit for both positive and negative wires from the AC incoming supply
  • ·         Not protected by the calculated and required 2 pole breakers for the input and output of the inverter
  • ·         Not installed with a changeover switch
  • ·         The battery input must be protected by a rated fuse for both the negative and positive connections, within the calculated PSCC ratings.
  • ·         Tampered with (attempted to open the unit)
  • ·         Visible damage to the unit

Write a review

Note: HTML is not translated!
    Bad           Good

MECER Axpert MKS Hybrid off-grid inverter 3kVA/3kW 1,500W MPPT 24V

  • R9,775.00

  • Excl. VAT: R8,500.00

Whatsapp us

Related Products

Voltronic Axpert VM 1kVA 1kW 500W MPPT Pf1

Voltronic Axpert VM 1kVA 1kW 500W MPPT Pf1

Cost-effective solar inverter This is a multi-functional inverter/charger, combining functions of ..

R4,830.00 Excl. VAT: R4,200.00

Voltronic Axpert VM III 5kVA 5kW 5000W MPPT Pf1

Voltronic Axpert VM III 5kVA 5kW 5000W MPPT Pf1

Axpert VM III is third generation off-grid inverter with rich new functions. Its detachable LCD con..

R12,000.00 Excl. VAT: R10,434.78

Voltronic Axpert VM III 3kVA 3kW 4000W MPPT Pf1 24V

Voltronic Axpert VM III 3kVA 3kW 4000W MPPT Pf1 24V

Axpert VM III is third generation off-grid inverter with rich new functions. Its detachable LCD con..

R8,500.00 Excl. VAT: R7,391.30

Tags: MECER-inverter, Axpert-inverter, Hybrid-inverter, off-grid, Inverter, 5kVA, 5kW, Voltronic-inverter

Related Product Bundle

Related Bundle Product

0

Shopping Cart

Your Shopping Cart is Empty!